NICET Level 1 inspection and Testing Exam 2025 Questions and Answers

NICET Level 1 inspection and Testing Exam 2025 Questions and Answers

Course:
NICET Level 1

Institution:
NICET Level 1

NICET Level 1 inspection and Testing Exam 2025 Questions and Answers

Preview (2 out of 8 pages)

NICET Level 1 inspection and Testing Exam 2025 Questions and Answers NICET Level 1 inspection and Testing Exam 2025 Questions and Answers

After purchase, you get:

✅ Instant PDF Download
✅ Verified answer explanations
✅ Refund if not Satisfied
✅ Prepared for 2025/2026 test cycle

Document Information
Uploaded on: September 3, 2025
Last updated: September 4, 2025
Number of pages:8
Written in:2025/2026
Type:Exam (elaborations)
Contains:Questions & Answers
Tags:NICET Level 1 inspection and Testing Exam 2025 Questions and Answers
Seller Information
Profile

SophiaBennett

Reviews Received
★★★★★
1
20
★★★★
1
8
★★★
1
5
★★
1
9
1
3
User Reviews (0)

Exam (Elaborations)

$9.50

Bundle Deal! Get all 15 docs for just $24.99

Add to Cart

100% satisfaction guarantee
Refund Upon dissatisfaction
Immediately available after purchase
Available in Both online and PDF

$9.50

| 0 sold

Discover More Resources

Available in a Bundle

Content Preview

NICET Level 1 inspection and Testing Exam 2025 Questions and Answers When using a pulse load tester on a sealed lead acid battery, the minimum acceptable capacity is... - ....ANSWER☑️☑️...-80% When a software change is made to a fire alarm system, what percentage of the initiating devices not affected by the change must be tested - ....ANSWER☑️☑️...10% When testing elevator recall, the elevator should go to the alternate level when: ....ANSWER☑️☑️...-The lobby smoke detector on the recall level is activated Minimum requirement for system documentation - ....ANSWER☑️☑️...-Battery calculations/floor plan/sequence of operations/voltage drop calculations Carbon monoxide detectors used for the toxicity of gas fired heating equipment must be tested annually per NFPA 72 - ....ANSWER☑️☑️...-False What is the maximum time period to replace a lead acid battery ....ANSWER☑️☑️...-Per manufacturers recommendation What type of instrument is normally used to test the specific gravity of lead acid battery cells - ....ANSWER☑️☑️...-Hydrometer Requirements of the branch circuit for the fire alarm control panel ....ANSWER☑️☑️...-Must be identified as fire alarm circuit.....must have a red marking......must be locked in the ON position if its a circuit breaker …FOR STUDY PURPOSES ONLY…©️ 2025 ALL RIGHTS RESERVED… 1